Skip to main content
  • Research article
  • Open access
  • Published:

Comparison of NIV-NAVA and NCPAP in facilitating extubation for very preterm infants

Abstract

Background

Various types of noninvasive respiratory modalities that lead to successful extubation in preterm infants have been explored. We aimed to compare noninvasive neurally adjusted ventilatory assist (NIV-NAVA) and nasal continuous positive airway pressure (NCPAP) for the postextubation stabilization of preterm infants.

Methods

This retrospective study was divided into two distinct periods, between July 2012 and June 2013 and between July 2013 and June 2014, because NIV-NAVA was applied beginning in July 2013. Preterm infants of less than 30 weeks GA who had been intubated with mechanical ventilation for longer than 24 h and were weaned to NCPAP or NIV-NAVA after extubation were enrolled. Ventilatory variables and extubation failure were compared after weaning to NCPAP or NIV-NAVA. Extubation failure was defined when infants were reintubated within 72 h of extubation.

Results

There were 14 infants who were weaned to NCPAP during Period I, and 2 infants and 16 infants were weaned to NCPAP and NIV-NAVA, respectively, during Period II. At the time of extubation, there were no differences in the respiratory severity score (NIV-NAVA 1.65 vs. NCPAP 1.95), oxygen saturation index (1.70 vs. 2.09) and steroid use before extubation. Several ventilation parameters at extubation, such as the mean airway pressure, positive end-expiratory pressure, peak inspiratory pressure, and FiO2, were similar between the two groups. SpO2 and pCO2 preceding extubation were comparable. Extubation failure within 72 h after extubation was observed in 6.3% of the NIV-NAVA group and 37.5% of the NCPAP group (P = 0.041).

Conclusions

The data in the present showed promising implications for using NIV-NAVA over NCPAP to facilitate extubation.

Peer Review reports

Background

Invasive mechanical ventilation (MV) is frequently required in preterm infants after birth to maintain adequate alveolar ventilation and effective gas exchange. However, tracheal intubation and MV in preterm neonates can induce ventilator-induced lung injury (VILI) and airway inflammation [1, 2]. Prolonged MV in preterm infants also increases the risk of ventilator-associated pneumonia, increasing the length of hospital stays, mortality, and neurologic impairment [3]. Therefore, noninvasive respiratory modalities have been used in preterm infants to facilitate the transition to spontaneous breathing following extubation [4,5,6,7].

Nasal continuous positive airway pressure (NCPAP) maintains functional residual capacity while improving lung compliance and oxygenation. NCPAP has been widely used in the neonatal intensive care unit (NICU) and has proven to be effective in preventing failure of extubation in preterm infants [8]. However, studies have reported that extubation failure rates ranged from 25 to 35% among preterm infants who were given NCPAP after extubation [9, 10]. Nasal intermittent positive pressure ventilation (NIPPV) augments NCPAP by superimposing ventilator inflation on NCPAP [11]. Although synchronized (SNIPPV) or nonsynchronized techniques can be used to supplement the infants’ own breathing efforts, it is likely that more effective support can be achieved with SNIPPV [12, 13]. To date, pneumatic capsules or flow sensors have been used to detect inspiration for synchronization, but some limitations in clinical practice have been reported [14,15,16].

Neurally adjusted ventilatory assist (NAVA) improves synchrony in patients with respiratory support by detecting the electrical activity of the diaphragm and may offer potential benefits in neonatal ventilation [17,18,19,20]. Noninvasive ventilation using NAVA as a triggering modality (NIV-NAVA) could be effective, as demonstrated in adult populations [21, 22]. To date, few studies of NIV-NAVA in preterm infants have been conducted. Patient-ventilator synchrony and effective diaphragmatic unloading were reported in preterm infants during NAVA-derived noninvasive nasal ventilation [23]. Herein, we aimed to compare NIV-NAVA and NCPAP for the postextubation stabilization of very low birth weight infants.

Methods

This study used a retrospective approach and was approved by the Institutional Review Board of Seoul National University Hospital. The study included preterm infants of less than 30 weeks gestational age (GA) who were admitted to the NICU of the Seoul National University Children’s Hospital (SNUCH) between July 2012 and June 2014 and survived more than 72 h. Infants who were on MV for longer than 24 h and were weaned to NCPAP (Infant Flow system, Viasys, Healthcare, Pennsylvania, United States) or NIV-NAVA (SERVO-I, Maquet Critical Care AB, Solna, Sweden) after extubation were eligible for the study. The size of the Edi catheter used during the study period was 6 Fr/49 cm, which could be used for extremely preterm infants [20]. There were no postmenstrual age (PMA) criteria for the use of NIV-NAVA during the study period if self-respiration was well established in the baby. Infants who had major congenital anomalies or who were intubated for longer than 6 weeks were excluded from the study. The study period was divided into two distinct periods, namely between July 2012 and June 2013 (Period I) and between July 2013 and June 2014 (Period II), because NIV-NAVA was applied at SNUCH beginning in July 2013.

The respiratory severity score (RSS = mean airway pressure (cmH2O) x FiO2) and oxygen saturation index (OSI = MAP x FiO2 × 100 ÷ SpO2) were used to compare the pre-extubation respiratory conditions between the two groups [24, 25]. The RSS has been used to predict extubation readiness or the length of mechanical ventilation in preterm infants, and the OSI has been suggested to be a useful measurement to reliably assess the severity of respiratory conditions in preterm infants when the oxygen index is not available [26, 27]. During the study period, extubation was performed if the patient remained stable with a SpO2 > 90% for at least 6 h while on the following settings: mean airway pressure (MAP) ≤ 9 cmH2O, positive end expiratory pressure (PEEP) ≤ 7 cmH2O and fraction of inspired oxygen (FiO2) ≤ 40%. In infants who were mechanically ventilated for longer than 15 days, dexamethasone was administered to reduce airway edema. All infants included in the study population were treated with caffeine. A capillary blood gas analysis was performed within 1 h after extubation. Postextubation PEEP was initially set to 5~6 cmH2O both in the NCPAP and NIV-NAVA groups, and was then adjusted within a range of 4~8 cmH2O according to the clinician’s discrimination. The NAVA level was initially set to 1.0~1.5 cmH2O/μV and adjusted to obtain pCO2 < 70 mmHg. In both ventilation strategies, binasal prongs and masks were used alternatively every 24 h to minimize nasal injury.

The primary outcome of the study was extubation failure within 72 h after extubation, which was defined according to a set of conditions for reintubation and the reapplication of MV [28]. Infants with severe apnea requiring positive pressure ventilation (PPV), ≥ 4 apneic episodes per hour needing moderate stimulation, FiO2 > 60%, or uncompensated respiratory acidosis (pH < 7.25) were reintubated during the study period. Backup ventilation at a rate of 30/min and pressure of 10–15 cmH2O above PEEP was applied if Edi was absent or apnea occurred for more than 5–10 s and the upper pressure limit was set to 20–25 cmH2O [23].

All statistical analyses were performed with STATA 11.0 (Stata Corp, College Station, TX, USA) using the independent t-test for continuous variables and the χ2-test and Fisher’s exact test for categorical variables. For all statistical analyses, P < 0.05 was considered statistically significant.

Results

A total of 64 infants in Period I and 51 infants in Period II who were born at less than 30 weeks of gestation and survived greater than 72 h were admitted (Fig. 1). Two infants from Period I were excluded: one infant had Beckwith-Wiedemann syndrome, and the other infant had Galen malformation of the brain. Sixteen infants in Period I and 13 infants in Period II who were never intubated or intubated less than 24 h were also excluded. After excluding infants who had been intubated for greater than 6 weeks, those who were never extubated or died before discharge, and those who were weaned to other modalities, such as heated and humidified high flow nasal cannula (HHHFNC), there were 14 infants who were weaned to NCPAP during Period I and 16 infants who were weaned to NIV-NAVA during Period II. The 2 infants who were weaned to NCPAP during Period II were categorized as the NCPAP group with the infants from Period I.

Fig. 1
figure 1

Selection of the study population during the study period

The GA and birth weight of the NIV-NAVA group and NCPAP group were not significantly different (27+ 1 vs. 26+ 5 weeks and 875 vs. 845 g, respectively) (Table 1). The incidence of RDS, maternal histologic chorioamnionitis and antenatal steroid use were also not significantly different between the two groups. At the time of extubation, PMA and weight exhibited no significant differences between the NIV-NAVA group and NCPAP group (30 vs. 29+ 4 weeks and 1045 vs. 1205 g, respectively) (Table 2). No differences in RSS (NIV-NAVA 1.65 vs. NCPAP 1.95), OSI (1.70 vs. 2.09) or steroid use were noted before extubation. Several ventilation parameters at extubation, such as MAP, PEEP, PIP peak inspiratory pressure (PIP), and FiO2, were similar between the two groups. SpO2 and pCO2 preceding extubation were also comparable.

Table 1 Demographics of the study population
Table 2 Clinical characteristics at the time of extubation

Extubation failure within 72 h after extubation was ascertained in 1 (6.3%) infant in the NIV-NAVA group and 6 (37.5%) infants in the NCPAP group (P = 0.041) (Table 3). One infant in the NIV-NAVA group was reintubated 11 h after extubation because of severe apnea requiring PPV. In the NCPAP group, 3 infants were reintubated before 24 h after extubation, 2 infants were reintubated 24–48 h after extubation and one infant was reintubated 70 h after extubation (Fig. 2). Three infants were reintubated because of severe apnea requiring PPV, two infants due to uncompensated respiratory acidosis (pH < 7.25) with pCO2 > 70 mmHg and one infant due to ≥4 apneic episodes per hour needing moderate stimulation. The use of other respiratory support parameters after extubation, such as PEEP and FiO2, were comparable between the NCPAP and NIV-NAVA groups with similar pCO2 and SpO2. Among those who were reintubated in the study, GA at birth was 26.4 weeks in the NIV-NAVA group and 25.9 (25.3–28.1) weeks in the NCPAP group. In the univariate logistic regression analysis, GA at extubation and the duration of invasive ventilation before extubation were not associated with reintubation (data not shown).

Table 3 Post-extubation status of the study population
Fig. 2
figure 2

Kaplan-Meier estimates for extubation success by post-extubation modality

No differences were noted between the two groups regarding the other clinical outcomes, including the development of moderate to severe bronchopulmonary dysplasia (BPD) (Table 4).

Table 4 Clinical outcomes of the study population

Discussion

Extubation failure is often observed in preterm infants because the chest wall and upper airway collapses easily and diaphragmatic strength is poor [29, 30]. The present study revealed that NIV-NAVA facilitated extubation better than NCPAP. Following a period of endotracheal intubation and IPPV, NCPAP is effective for preventing extubation failure in preterm infants [8]. This technique appears to improve lung function and reduce apnea and may therefore play a role in facilitating extubation in this population. However, certain populations among preterm infants who were subject to NCPAP experienced extubation failure [6, 31,32,33].

NIPPV augments NCPAP by delivering ventilator breaths via nasal prongs or a mask. Although it did not improve ventilation in infants who were able to maintain their own ventilation on NCPAP, in infants with a higher baseline PaCO2, ventilation was more effectively increased by NIPPV than NCPAP [34]. Severe apnea and increased PaCO2 were the most common causes of failure in infants receiving NCPAP, and NIPPV achieved a comparative reduction in extubation failure in preterm infants. A recent meta-analysis demonstrated that the incidence of extubation failure and the need for reintubation within 48 h to 1 week was reduced by NIPPV in preterm infants [12]. However, synchronization and the device used to deliver PPV may be important parameters in NIPPV [13].

NAVA has been applied in clinical practice during the last decade, but studies have rarely involved neonates, especially the preterm infant population. However, a recent study demonstrated the effectiveness and feasibility of NAVA in this population [19]. Noninvasive support via NAVA improved patient-ventilator synchrony by reducing trigger delay and the number of asynchrony events [35]. Previously, we reported that NAVA improved patient-ventilator synchrony and diaphragmatic unloading in preterm infants during noninvasive nasal ventilation compared with pressure support mode [23]. A recent physiologic study performed by Gibu et al. compared NIV-NAVA and NIPPV and demonstrated that peak inspiratory pressure and FiO2 were lowered in NIV-NAVA than in NIPPV [36]. Furthermore, both infant movement and caretaker’s work were lowered in NIV-NAVA, suggesting that NIV-NAVA was more effective than NIPPV at increasing infant comfort. Because it has excellent synchronization, NIN-NAVA could serve as a substitute for NCPAP to facilitate extubation in preterm infants. Most cases of reintubation in this study were the result of severe apnea or uncompensated hypercapnia. When compared to NCPAP, apnea and hypercapnia were more preventable in NIPPV by generating higher airway pressure to prevent obstructive apnea and triggering sigh in preterm infants [37, 38]. Although NIV-NAVA seemed to improve ventilator synchrony and diaphragmatic unloading during noninvasive ventilation compared to other NIPPV, there was no evidence that NIV-NAVA is superior to other NIPPV modalities after extubation [23, 39].

Even though there could be concerns regarding the size of the baby when using NIV-NAVA, many studies showed NIV-NAVA was feasible in extremely preterm infants [23, 39]. In the present study, NIV-NAVA was also found to be feasible in babies as small as 660 g at extubation or 700 g at birth who were successfully weaned to NIV-NAVA at PMA 28 weeks. A baby who was 500 g at birth was also successfully weaned to NIV-NAVA at 770 g. Moreover, Edi catheters can efficiently serve as a feeding tube in these babies and thus an additional feeding tube did not need to be inserted for enteral feeding. NEC was comparable in both groups and there were no intestinal perforations or air leaks after the infants were weaned to NIV-NAVA or NCPAP. Although the rates of neonatal complications are lower in noninvasive versus invasive MV, safety must be considered. Previously, it was suggested that neonates who were mechanically ventilated with either a face mask or nasal prongs had an increased risk of gastrointestinal perforations. However, recent data has shown that NIPPV does not appear to be associated with increased gastrointestinal side effects, and the risk of air leaks was lower in NIPPV than in NCPAP [40]. No differences in the development of air leaks and NEC were observed between the two groups in the present study.

There are some limitations to the present study. This study was a retrospective study with a small sample size, thus making it difficult to draw robust conclusions. There also was a period of overlap when both NIV-NAVA and NCPAP were used as weaning modalities. The study population was highly selected because we analyzed only 50% of the preterm infants born at < 30 weeks of gestation who were intubated for more than 24 h and were extubated thereafter during the study period. Furthermore, the duration of ventilation seemed to be shorter in the NCPAP group, although this result was not statistically significant. While the sample size may have been too small to fully elucidate this difference, a logistic regression analysis for reintubation was performed ad hoc and showed that the duration of ventilation before extubation was not associated with reintubation (data not shown). The criteria for extubation were well-defined in our unit, and the pre-extubation conditions in both groups including the PMA at extubation, RSS, OSI and the ventilation settings were comparable in the present study. Despite these limitations, this is the first study to compare the clinical responses between NIV-NAVA and NCPAP when used to facilitate extubation in preterm infants.

Conclusions

The data in the present study were not robust enough to be conclusive due to small sample size, but showed promising implications for using NIV-NAVA over NCPAP to facilitate extubation. NIV-NAVA could be an effective modality for synchronized noninvasive ventilation following successful extubation from MV in preterm infants.

Availability of data and materials

The dataset generated or analyzed during this study can be made available to interested researchers by the authors of this article upon reasonable request.

Abbreviations

HHHFNC:

Humidified high flow nasal cannula

MAP:

Mean airway pressure

MV:

Mechanical ventilation

NAVA:

Neurally adjusted ventilatory assist

NCPAP:

Nasal continuous positive airway pressure

NICU:

Neonatal intensive care unit

NIPPV:

Nasal intermittent positive pressure ventilation

NIV-NAVA:

Non-invasive ventilation using NAVA

OSI:

Oxygen saturation index

PEEP:

Positive end expiratory pressure

PPV:

Positive pressure ventilation

RSS:

Respiratory severity score

SNIPPV:

Synchronized Nasal intermittent positive pressure ventilation

VILI:

Ventilator-induced lung injury

References

  1. Donn SM, Sinha SK. Minimising ventilator induced lung injury in preterm infants. Arch Dis Child Fetal Neonatal Ed. 2006;91(3):F226–30.

    Article  CAS  Google Scholar 

  2. Carvalho CG, Silveira RC, Procianoy RS. Ventilator-induced lung injury in preterm infants. Rev Bras Ter Intensiva. 2013;25(4):319–26.

    Article  Google Scholar 

  3. Apisarnthanarak A, Holzmann-Pazgal G, Hamvas A, Olsen MA, Fraser VJ. Ventilator-associated pneumonia in extremely preterm neonates in a neonatal intensive care unit: characteristics, risk factors, and outcomes. Pediatrics. 2003;112(6 Pt 1):1283–9.

    Article  Google Scholar 

  4. Moretti C, Giannini L, Fassi C, Gizzi C, Papoff P, Colarizi P. Nasal flow-synchronized intermittent positive pressure ventilation to facilitate weaning in very low-birthweight infants: unmasked randomized controlled trial. Pediatr Int. 2008;50(1):85–91.

    Article  Google Scholar 

  5. Khalaf MN, Brodsky N, Hurley J, Bhandari V. A prospective randomized, controlled trial comparing synchronized nasal intermittent positive pressure ventilation versus nasal continuous positive airway pressure as modes of extubation. Pediatrics. 2001;108(1):13–7.

    Article  CAS  Google Scholar 

  6. Dimitriou G, Greenough A, Kavvadia V, Laubscher B, Alexiou C, Pavlou V, Mantagos S. Elective use of nasal continuous positive airways pressure following extubation of preterm infants. Eur J Pediatr. 2000;159(6):434–9.

    Article  CAS  Google Scholar 

  7. Peake M, Dillon P, Shaw NJ. Randomized trial of continuous positive airways pressure to prevent reventilation in preterm infants. Pediatr Pulmonol. 2005;39(3):247–50.

    Article  CAS  Google Scholar 

  8. Davis PG, Henderson-Smart DJ. Nasal continuous positive airways pressure immediately after extubation for preventing morbidity in preterm infants. Cochrane Database Syst Rev. 2003;2:CD000143.

  9. Ignacio L, Alfaleh K. High-flow nasal cannulae in very preterm infants after extubation. J Clin Neonatol. 2014;3(1):11–3.

    Article  Google Scholar 

  10. Davis P, Henderson-Smart D. Post-extubation prophylactic nasal continuous positive airway pressure in preterm infants: systematic review and meta-analysis. J Paediatr Child Health. 1999;35(4):367–71.

    Article  Google Scholar 

  11. De Paoli AG, Morley C, Davis PG. Nasal CPAP for neonates: what do we know in 2003? Arch Dis Child Fetal Neonatal Ed. 2003;88(3):F168–72.

    Article  Google Scholar 

  12. Bancalari E, Claure N. The evidence for non-invasive ventilation in the preterm infant. Arch Dis Child Fetal Neonatal Ed. 2013;98(2):F98–F102.

    Article  Google Scholar 

  13. Huang L, Mendler MR, Waitz M, Schmid M, Hassan MA, Hummler HD. Effects of synchronization during noninvasive intermittent mandatory ventilation in preterm infants with respiratory distress syndrome immediately after extubation. Neonatology. 2015;108(2):108–14.

    Article  CAS  Google Scholar 

  14. Hird MF, Greenough A: Comparison of triggering systems for neonatal patient triggered ventilation. Arch Dis Child 1991, 66(4 Spec No):426–428.

    Article  CAS  Google Scholar 

  15. John J, Bjorklund LJ, Svenningsen NW, Jonson B. Airway and body surface sensors for triggering in neonatal ventilation. Acta Paediatr. 1994;83(9):903–9.

    Article  CAS  Google Scholar 

  16. Courtney SE, Barrington KJ. Continuous positive airway pressure and noninvasive ventilation. Clin Perinatol. 2007;34(1):73–92 vi.

    Article  Google Scholar 

  17. Stein H, Firestone K. Application of neurally adjusted ventilatory assist in neonates. Semin Fetal Neonatal Med. 2014;19(1):60–9.

    Article  Google Scholar 

  18. Sinderby C, Navalesi P, Beck J, Skrobik Y, Comtois N, Friberg S, Gottfried SB, Lindstrom L. Neural control of mechanical ventilation in respiratory failure. Nat Med. 1999;5(12):1433–6.

    Article  CAS  Google Scholar 

  19. Beck J, Reilly M, Grasselli G, Mirabella L, Slutsky AS, Dunn MS, Sinderby C. Patient-ventilator interaction during neurally adjusted ventilatory assist in low birth weight infants. Pediatr Res. 2009;65(6):663–8.

    Article  Google Scholar 

  20. Lee J, Kim HS, Sohn JA, Lee JA, Choi CW, Kim EK, Kim BI, Choi JH. Randomized crossover study of neurally adjusted ventilatory assist in preterm infants. J Pediatr. 2012;161(5):808–13.

    Article  Google Scholar 

  21. Schmidt M, Dres M, Raux M, Deslandes-Boutmy E, Kindler F, Mayaux J, Similowski T, Demoule A. Neurally adjusted ventilatory assist improves patient-ventilator interaction during postextubation prophylactic noninvasive ventilation. Crit Care Med. 2012;40(6):1738–44.

    Article  Google Scholar 

  22. Azoulay E, Kouatchet A, Jaber S, Lambert J, Meziani F, Schmidt M, Schnell D, Mortaza S, Conseil M, Tchenio X, et al. Noninvasive mechanical ventilation in patients having declined tracheal intubation. Intensive Care Med. 2013;39(2):292–301.

    Article  Google Scholar 

  23. Lee J, Kim HS, Jung YH, Shin SH, Choi CW, Kim EK, Kim BI, Choi JH. Non-invasive neurally adjusted ventilatory assist in preterm infants: a randomised phase II crossover trial. Arch Dis Child Fetal Neonatal Ed. 2015;100(6):F507–13.

    Article  Google Scholar 

  24. Iyer NP, Mhanna MJ. Non-invasively derived respiratory severity score and oxygenation index in ventilated newborn infants. Pediatr Pulmonol. 2013;48(4):364–9.

    Article  Google Scholar 

  25. Muniraman HK, Song AY, Ramanathan R, Fletcher KL, Kibe R, Ding L, et al. Evaluation of oxygen saturation index compared with oxygenation index in neonates with hypoxemic respiratory failure. JAMA Netw Open. 2019;2(3):191–79.

    Article  Google Scholar 

  26. Malkar MB, Gardner WP, Mandy GT, Stenger MR, Nelin LD, Shepherd EG, Welty SE. Respiratory severity score on day of life 30 is predictive of mortality and the length of mechanical ventilation in premature infants with protracted ventilation. Pediatr Pulmonol. 2015;50(4):363–9.

    Article  Google Scholar 

  27. Mhanna MJ, Iyer NP, Piraino S, Jain M. Respiratory severity score and extubation readiness in very low birth weight infants. Pediatr Neonatol. 2017;58(6):523–8.

    Article  Google Scholar 

  28. Chawla S, Natarajan G, Gelmini M, Kazzi SN. Role of spontaneous breathing trial in predicting successful extubation in premature infants. Pediatr Pulmonol. 2013;48(5):443–8.

    Article  Google Scholar 

  29. Gerhardt T, Bancalari E. Chestwall compliance in full-term and premature infants. Acta Paediatr Scand. 1980;69(3):359–64.

    Article  CAS  Google Scholar 

  30. Dransfield DA, Spitzer AR, Fox WW. Episodic airway obstruction in premature infants. Am J Dis Child. 1983;137(5):441–3.

    CAS  PubMed  Google Scholar 

  31. Ammari A, Suri M, Milisavljevic V, Sahni R, Bateman D, Sanocka U, Ruzal-Shapiro C, Wung JT, Polin RA. Variables associated with the early failure of nasal CPAP in very low birth weight infants. J Pediatr. 2005;147(3):341–7.

    Article  Google Scholar 

  32. Reininger A, Khalak R, Kendig JW, Ryan RM, Stevens TP, Reubens L, D'Angio CT. Surfactant administration by transient intubation in infants 29 to 35 weeks’ gestation with respiratory distress syndrome decreases the likelihood of later mechanical ventilation: a randomized controlled trial. J Perinatol: official journal of the California Perinatal Association. 2005;25(11):703–8.

    Article  CAS  Google Scholar 

  33. Stefanescu BM, Murphy WP, Hansell BJ, Fuloria M, Morgan TM, Aschner JL. A randomized, controlled trial comparing two different continuous positive airway pressure systems for the successful extubation of extremely low birth weight infants. Pediatrics. 2003;112(5):1031–8.

    Article  Google Scholar 

  34. Ali N, Claure N, Alegria X, D'Ugard C, Organero R, Bancalari E. Effects of non-invasive pressure support ventilation (NI-PSV) on ventilation and respiratory effort in very low birth weight infants. Pediatr Pulmonol. 2007;42(8):704–10.

    Article  Google Scholar 

  35. Vignaux L, Grazioli S, Piquilloud L, Bochaton N, Karam O, Levy-Jamet Y, Jaecklin T, Tourneux P, Jolliet P, Rimensberger PC. Patient-ventilator asynchrony during noninvasive pressure support ventilation and neurally adjusted ventilatory assist in infants and children. Pediatr Crit Care Med. 2013;14(8):e357–64.

    Article  Google Scholar 

  36. Gibu C, Cheng P, Ward RJ, Castro B, Heldt GP. Feasibility and physiological effects of non-invasive neurally-adjusted ventilatory assist (NIV-NAVA) in preterm infants. Pediatr Res. 2017;82(4):650–7.

    Article  Google Scholar 

  37. Lin CH, Wang ST, Lin YJ, Yeh TF. Efficacy of nasal intermittent positive pressure ventilation in treating apnea of prematurity. Pediatr Pulmonol. 1998;26(5):349–53.

    Article  CAS  Google Scholar 

  38. Bisceglia M, Belcastro A, Poerio V, Raimondi F, Medsuraca L, Crugliano C, Corapi UP. A comparison of nasal intermittent versus continuous positive pressure delivery for the treatment of moderate respiratory syndrome in preterm infants. Minerva Pediatr. 2007;59(2):91–5.

    CAS  PubMed  Google Scholar 

  39. Yonehara K, Ogawa R, Kamei Y, Oda A, Kokubo M, Hiroma T, Nakamura T. Non-invasive neurally adjusted ventilatory assist versus nasal intermittent positive-pressure ventilation in preterm infants born before 30 weeks’ gestation. Pediatr Int. 2018;60(10):957–61.

    Article  Google Scholar 

  40. Lemyre B, Davis PG, De Paoli AG, Kirpalani H. Nasal intermittent positive pressure ventilation (NIPPV) versus nasal continuous positive airway pressure (NCPAP) for preterm neonates after extubation. Cochrane Database Syst Rev. 2017;2:CD003212.

    PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This study was supported by a grant from the Seoul National University Hospital Research Fund (04–2015-0430) and by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (2017R1D1A1B03036383). The funders did not participate in the research, or in the preparation the manuscript.

Author information

Authors and Affiliations

Authors

Contributions

SHS, BKL and H-SK conceived and designed the study, collected and analyzed the data and drafted the manuscript. E-KK and YHJ revised the manuscript for critically important intellectual content. SHS, BKL and H-SK finalized the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Seung Han Shin.

Ethics declarations

Ethics approval and consent to participate

Ethical approval to conduct this study was obtained from the Institutional Review Board of Seoul National University Hospital. Written consent from the caregivers of the neonates could not be obtained due to the retrospective nature of the study. However, all the patient-related information was anonymized.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lee, B.K., Shin, S.H., Jung, Y.H. et al. Comparison of NIV-NAVA and NCPAP in facilitating extubation for very preterm infants. BMC Pediatr 19, 298 (2019). https://doi.org/10.1186/s12887-019-1683-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12887-019-1683-4

Keywords