Skip to main content

Table 1 Routine sequences and parameters of MRI examinations in the study

From: Magnetic resonance imaging follow-up can screen for soft tissue changes and evaluate the short-term prognosis of patients with developmental dysplasia of the hip after closed reduction

Sequence

TR (ms)

TE (ms)

Bandwidth (kHz)

FOV (cm)

Slice thickness (mm)

Slice gap (mm)

Matrix

NEX

Coronal FS PDWI

2500

40

85

22 × 22

3.5

0.5

320 × 224

3

Transverse FS PDWI

2500

40

63

22 × 22

3.5

0.5

320 × 256

3

Coronal T2WI

3000

85

85

24 × 16

3.5

0.5

320 × 224

6

  1. MRI magnetic resonance imaging, TR repetition time, TE echo time, FOV field of view, NEX number of excitations, TA acquisition time, FS fat suppression, PDWI proton density-weighted imaging