Fig. 3 | BMC Pediatrics

Fig. 3

From: High inter-observer reliability in standardized ultrasound measurements of subcutaneous adipose tissue in children aged three to six years

Fig. 3

Observer differences from the mean. Individual observer differences (Δ) from the mean of the three measurements (DMEAN) are shown for each participant (see Table 2). a Individual observer differences from DMEAN including embedded structures (DI,MEAN) calculated as ΔI = DIDI,MEAN are shown. Standard deviation (SD) of observer differences was 1.1 mm, 95% of the measurements were between ±2.1 mm (limits of agreement). b Individual observer differences ΔE = DIDE,MEAN are shown. SD of observer differences was 1.0 mm, 95% of measurements were between ±2.0 mm (limits of agreement)